My intermatic timer is about two years old as well. Check the wire connections to be sure they are tight, and look for any burnt wires. As you release the dial, you will feel the gears engage. Hi Casey, perhaps the cord or wires are broken? Why it always stop around 10pm by itself and not moving again? It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. Any suggestions? what causes timer on/off pins to bend and how can i prevent timer pins from bending. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. HELP! Is the timer repairable, or should I just install a new one? The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Are the gears engaged, in the center, behind the dial? To set it, you just move the on/off "trippers" where you want them. Hi Jeff, it could be that the terminals in the rear of the clock mechanism are fuse-welded together, and not separating like normal, when the on/off switch is flipped. Turn the power off at the breaker box and carefully remove the wires to the clock. be sure the pins are pushed onto the edge of the dial fully. Reddit - Dive into anything Please advise. If you are not sure if your timer is working or not you will first need to know if its even operational. If you have gone back after a few hours and the pins have moved that means you have electrical power to your timer and it is working. Look into the visual motor check window, near the top of the timer mechanism. Other than a couple of weeks, we have spent fifteen years manually turning on our pump. "url": "https://blog.intheswim.com/"
Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. Types of Pool Timers & How They Work - Pool Research You will want to make sure the manual switch under the timer wheel is pushed to the on position. Thank you so much. http://waterheatertimer.org/Tork-timers-and-manuals.html You can replace the timer motor only, or the entire clock, both fairly easy to swap out. That will do it. I am having the same problem. I have the same issue currently, and it makes no sense to me so far. 3. Or might find something else. Read Book Tork Trippers Manual Guide Pdf For Free - twiki.skotos I have a T104. Please let me know if you find the solution! (For outside light timer) The one before was original to the house & I had no trouble. I have replaced the trippers, but the problem persists. If your timer pins have not moved that means there is no power to the timer or the timer has failed and need to be replaced or possible manual over ride switch for the timer is off. I have the Intermatic T103 autotimer on my pool. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. Ive reset the time 5 times and just realized that its going counter clockwise. Is it Necessary? When I turned it back on now the pool clock goes backwards. Slide it around the pool timer dial to the correct start time and re-tighten it. If it doesnt, there could be an issue with the clock face or gears. To do this, pull the yellow-faced time dial (clockface) toward you. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. Just installed a new timer. Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. Did the power recently go out or has the circuit breaker tripped? Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. Im wanting to use T101 to wire my above ground pool pump. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. First, verify the power is turned off at the breaker panel. You will have live wires exposed and they can kill you if you touch them. PDF Model: T104 24 Hour Dial Time Switch It is not warped in any way. A timer that switches on and off at the wrong times usually occurs after a power outage. "height": "219",
Pool pump timers can last up to 20 years, depending on the model. Read full answer 2/14/2023 3:20:07 AM Start with the easy checks. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. 2nd black goes to -2 I currently manually turn it on and off. You can replace the entire mechanism or the gears. The other gears move very slowly, and appear to not move at all, except for one I believe? I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. The clock will also be missing 3-hours of time, so will need to be reset to the current time. 12 Best Pool Pump Timers For Reducing Your Power Bill! The tripper will not move. The trippers can also get damaged. It stays on until I turn off the circuit breaker. Any ideas why its doing that? To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. Welcome to Pool Spa Outpost! So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. "url": "https://intheswim.com/",
TORK Repair Questions & Solutions, Tips & Guides - Fixya You may need to adjust the meshing of the timer motor gear so it runs the clock. Faulty Pump or Wiring from the Timer to the Pump. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. The A terminal is not normally used, unless you have a 3 wire service. Okay, so lets move on to the Intermatic Pool Timer troubleshooting and figure out why your timer is not working. Trippers are not installed properly Re-install trippers on dial 2. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. That should quiet it down. Does the tripper work on other areas of the clock, like near the off tripper? I dont see timer gears rotating on any power going to the pump or salt system. The timer seems to get stuck prior to reaching the on trippers therfore the pump cant turn on. Black goes to _1 Off flipper always works. I replaced the pump and still nothing is moving. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. I took the electrical box cover off and check the breaker connections. Hi Matthew T104 can only turn one pump on and off. Any suggestions? Check that the TEST button has not popped out. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. Proceed to step 4 to check the timer itself. It is generally not recommended to reuse a critical fastener like the rear spinal nut on your 2000 Ford Focus. Basically 12 real life hours equals about 14 on the timer. How about the GFCI outlet TEST button, is it tripped? Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. I think I have found it. Basically youre eliminating possibilities until you find the cause. Did you try to flip the switch of the timeclock? Any advice? It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. What Im wanting to do is just disable the turn off/on and just keep power 24/7. Death By Audio / Levitation Speed Tripper Feedback Phasing Delay But of the timer itself is bad you will need a licensed electrician to change the timer for you. Ask Your Own Pool and Spa Question Theres really only 3 causes as to why your pump wont turn on/off. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. I flicked the switch between on and off and it will not shut off. Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. I went to the control panel and saw that the timer needle stopped just after the start pointer. Hi Rhomell, are you sure you got the correct trippers? Or may be bent and not come together. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. However the new breaker is in a constantly tripped position. I need to replace a timer for my pool vacuum. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. How can it keep time if lever is in off position (manual lever). Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Hi Joe, could be time, for new timer. Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. Can breaker be bad? Partially loosen the screw that holds the "off" pin in place. Clock not turning or making any sound. Amazon.com: pool timer trippers There is a switch control panel and replaced the 20amps DP switch as well. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. I can turn the pool pump on via the manual power lever thats located at 5 O clock on the timer. I can, however, hear an intermittent click as if the mechanism is trying to switch on. Resolved! For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Confused. Thanks for the suggestions.. Also, once it reaches the tripper, the gears in the window no longer move. Your timer is on a 24-hour cycle. It randomly loses the time that it is set to. It sounds like the Line and Load wires are reversed. Learn more about pool care and repair. 110V or 220V? Once you do some you will want to re-tighten the hold down screw on the timer pin so it stays in place. Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. Posted by 4 years ago. Is the ON tripper all the way pushed onto the dial? Not sure if i need to check out the wiring, but it is a bit frustrating. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. Not two OFF trippers? Thank you. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. Still no luck. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. Does the motor gradually start running slowly? There could also be other mechanical reasons for this happening, such as a disconnect in the switch. AJH Trade Group also participate in other affiliate programs. If any of these issues occur your timer will not work properly. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. That way I could schedule the pump once again. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). Pool co says T104 timer needs replacement and filter cartridge. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. 2425 Glenview Dr, HOLLISTER, CA 95023 | MLS# ML81913834 | Redfin It was always fine before. Does the manual lever stay in the on position always? Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. The old "off" tripper was fractionally bent. No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. Check the motor, and be sure the label is not printed 50 hz. "keywords": "",
i have a P1121 intermatic timer connected to a hayward above ground pool pump. Thanks. If the pool timer is not keeping the correct time or losing time, there may be a simple fix. This div height required for enabling the sticky sidebar. Tighten down all brass screws securely, to hold all wires firmly in place. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. "@context": "https://schema.org/",
Paul, it could be that you got a 50hz motor, instead of a 60hz? Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. Align the bar with the current time and push it back into place. Just replace it and hope for one that isnt defective. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Is that a faulty motor? If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. When the power goes out, the timer stops. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. 1100 Juanita St, Austin, TX 78704 | MLS #6354744 | Zillow South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveler reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. You can find this in your power board. Turn the manual on/off switch. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. I noticed that they had stopped. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. After a power failure the timer clock can start up backwards, mine has done this several times. Some white lithium grease on the switch can help in some cases. "dateModified": "1/10/2020",
Set the current time to the center time pointer, pointing downward at 6 oclock. Video of the Day Trippers Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. Look for any disconnected or damaged wires leading to the motor on the rear of the clock. These clocks determine when your pool pump turns on, and how long it runs. My Tork TU40 pool pump timer wont turn on the pump. The red - JustAnswer Pool Timer Clock Parts and Trippers When you flip the switch does it separate and reconnect the tabs? i have an oval pool that is closed for the winter but there ha been a problem. It I set the timer again it will jeep time until it gets to the next dog ear. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. ft. home is a 3 bed, 4.0 bath property. However, the timer will stop around 10pm everyday and will not continue moving forward again. Give it a little squirt of WD-40 or similar lubricant. But my new timer will not work either. Thank you. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. You can have as many ON an OFF trippes as you want. Is it toast ? I look through the window of the panel and see the gears running well. As it get cooler you can cut it down to 5 or 6 hr a day . "primaryImageOfPage": {
Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. The 12 Best Pool Timers of 2022 - WildRiver You need that 8 hr run in just the summer . I have an Intermatic t104. Push the tab on the top, and let the mechanism fall forward. Intermatic Mechanical Timer Mechanism Only, 40 Amp, 220 Volt, DPST, 24